Flare systems are used at hazardous production facilities for the extraction, collection and product preparation from oilfields, gas and gas condensate fields in chemical, petrochemical, oil and gas processing, oil and gas industry
Design
1. the equivalent diameter of the outlet nozzle of the flare tip can be varied depending on the relief gas flow
2. smokeless/sootless combustion is provided for the entire relief gas flow range without additional air or steam supply
Parameter
Value
Working environment
associated petroleum gas, natural gas, various gases from process units
Flare unit capacity, nm3/hour
according to customer requirements, permanent/emergency discharge
Operating pressure, MPa (excess pressure)
up to 0,3 and above
Discharge gas temperature, °С
-30 ÷ +300
Average service life before overhaul, h, not less
20 000
Fuel gas consumption for reserve/pilot burners
25
Operating pressure of the fuel gas supplied to the pilot burner, MPa (excess pressure)
0,2 - 0,3
Flame shaft diameter, mm
150 ÷ 1400
Height of the flare unit, mm
10 000 - 120 000
Flame tip diameter, mm
50 - 900
Number of pilot burners, pcs.
1 - 5
Service life, years
up to 30
Power consumption, W, max
200 - 400
Unit type
Smokeless / sootless
control unit (gas treatment unit)
ignition and control system
flare unit
flare stack
flare tip
flash burners
control (local) panel
control cabinet (located locally or in the operator room)
instrumentation within the scope of supply
valving within the scope of supply
spare parts, gaskets, counter flanges
cable products, terminal boxes, electrical and wiring products, cable-support systems within the scope of supply
patented flare tip
smokeless/sootless in the entire range of gas flow rates from the minimum possible (purge) to the maximum gas relief