Tube Heat Exchangers with floating head with a U-tubes
Devices are designed to heat liquids and gases in industrial processes refining, petrochemical, chemical, oil, gas and other industries and are manufactured according to the ТS 3612-023-00220302-01.
The cooling environment in refrigerators and condensers is water or another nontoxical, not explosive and not flammable liquid with a boiling temperature with a pressure of 0,07 MPa over 60°С.
Devices can be used in a climatic regions with temperate and tropical climates. Climatic modification «U» и «Т», category of a product 1 according to GOST 15150.
The devices are designed to be installed in geographic areas seismicity to 7 points in the Russian Federation adopted on 12-point scale.
When choosing vehicles produced heat engineering calculations, as well as selected materials that provide resistance to the corrosive effects of environments.
The main parameters of devices such as TU
Parameter
| Value | |
Heat exchange surface, m²
| 12-1370 | |
Diameter of a casing, mm
| outer | 325 |
internal | 400*; 500*; 600*;700*; 800; 900; 1000; 1200; | |
Temperature of the heatexchanging environments, °С
| tubes | from -30 to +450
|
case | ||
Nominal pressure,
MPa, in the case for devices with a diameter, mm | 325 | 2,5;4,0 |
400 | 2,5; 4,0; 6,3 | |
500 | 2,5; 4,0; 6,3 | |
600 and 700 | 1,6; 2,5; 4,0; 6,3 | |
800 | 1,6; 2,5; 4,0; 6,3 | |
900 and 1000 | 1,6; 2,5; 4,0 | |
1200 | 1,6; 2,5 | |
Nominal pressure,
MPa, in the pipes for devices with a diameter, mm | 325 | 2,5; 4,0 |
400 | 2,5; 4,0; 6,3 | |
500 | 2,5; 4,0; 6,3 | |
600 and 700 | 1,6; 2,5; 4,0; 6,3 | |
800 | 1,6; 2,5; 4,0; 6.3 | |
900 and 1000 | 1,6; 2.5; 4,0 | |
1200 | 1,6; 2,5 | |
1400 | 1,6; 2,5 | |
Straight length of heat exchanger pipes, mm for devices with a diameter, mm
| 325;400;500 | 3000; 6000 |
600 and 700 | 6000 | |
800; 900; 1000; 1200 | 6000; 9000 | |
1400 | 6000; 9000 | |
The outer diameter and wall thickness of the heat exchange pipes (diameter and thickness)
| 20x2; 25x2; 25x2,5 | |
Number of moves through the pipes for machines in diameter, mm
| 325; 400; 500 | 2 |
600; 700; 800; 900; 1000; 1200 | 2 | |
1400 | 2 | |
Arrangement of heat exchanger pipes in tube sheets and partitions
| at the vertices of equilateral triangles |
Limit design pressure depending on the estimated ambient temperature for devices such as TU
Pressure in the case, Ру
MPa, max | Limiting the design pressure, MPa, at the reference temperature environment, °С
| |||||||
up to 100 | 200 | 250 | 300 | 350 | 400 | 425 | 450 | |
1,0 | 1,00 | 0,93 | 0,90 | 0,075 | 0,66 | 0,58 | - | - |
1,6 | 1,60 | 1,49 | 1,40 | 1,20 | 1,10 | 0,90 | 0,80 | 0,57 |
2,5 | 2,50 | 2,32 | 2,25 | 1,90 | 1,70 | 1,50 | 1,30 | 0,90 |
4,0 | 4,00 | 3,72 | 3,50 | 3,00 | 2,60 | 2,30 | 2,00 | 1,40 |
6,3 | 6,30 | 6,00 | 5,40 | 4,80 | 4,00 | 3,70 | 3,20 | 2,30 |
8,0 | 8,00 | 7,00 | 6,80 | 6,00 | 5,20 | 4,60 | 4,00 | 3,20 |
Example of designation heat exchanger when ordering:
The heat exchanger with a U-shaped pipes (TU), with a case diameter of 1400 mm,
conditional on the pressure in the pipes and case 1.6 MPa, executions on material Ml, with smooth heatexchange pipes (G), diameter 25 mm, 6 m long, at the vertices of equilateral triangles (T), 2-way on the pipe space, climatic modification (U), with parts for fixing insulation:
Heat exchanger 1400 ТU-1,6-М1/25G-6-Т-2-U-I ТS 3612-023-00220302-00
Example of designation of pipe bunch when ordering (self-supply):
The heat exchanger with a U-shaped pipes (TU), with a case diameter of 1400 mm,
conditional on the pressure in the pipes and casing 2.5 MPa, executions on material Ml, with smooth heatexchange pipes (G), diameter 25 mm, 6 m long, at the vertices of equilateral triangles (T), 2-way on the pipe space, climatic modification (U):
Heat exchanger 1400 ТU-2,5-М1/25G-6-Т-2-U ТS 3612-023-00220302-00